Page 10
2) WORD CLOCK IN and WORD CLOCK OUT
BNC connectors.
WORD CLOCK IN Allows Aurora to synchronize to an external clock source. With a valid
clock source connected, choose “EXT” or “EXT/2” from SYNC SOURCE
(use “EXT/2” when you wish to operate in dual-wire mode). For best
results, wait until SynchroLock achieves full lock (when the SynchroLock
LED turns solid) before converting audio.
WORD CLOCK OUT Allows external devices to synchronize to the Aurora sample clock
generator. The Aurora will pass clock out this port when it is a clock
master or clock slave.
2! AC POWER INLET
For connection of AC power to the Aurora.
Please note that the Aurora comes factory-configured for a specific
voltage range, and cannot be changed in the field. The acceptable
voltage range of the Aurora is printed on the label affixed to the top
cover of the Aurora just above the AC power inlet. Failure to connect
the Aurora to an AC power source that conforms to the requirements
printed on the label may damage the Aurora and require it to be
returned to the factory for non-warranty repair.